AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |
Back to Blog
Contour next test strips11/19/2023 ![]() The enzyme on the strip enables the device to ‘read’ the current between the terminals, using an algorithm to determine the glucose concentration in the blood. After a drop of blood is placed on the strip, it’s inserted into the glucose meter device, which transmits a small current of electrons to the end of the strip. This enzyme produces gluconic acid when combined with a blood sample. A small area at the tip of the strip is coated with an enzyme known as glucose oxidase. Glucose test strips are primarily made of thin, flexible plastic. Blood sugar levels rise and fall throughout the day, but diabetics must carefully monitor such changes. These readings provide valuable information that determine whether insulin or food or liquid intake is needed to boost levels, and whether adapting activities during certain times of the day is required. They may not look so special, but these strips enable glucometer devices to ‘read’ glucose levels in the blood. Hematocrit The results provided by the Contour Next test strips are not significantly modified when the hematocrit value is between 0% and 70%ĭo not use during or shortly after the xylose absorption test.Diabetic test strips are an important part of blood sugar (glucose) monitoring.Paracetamol> 35 mg / dl (> 2.3 mmol / l).Ascorbic acid> 10 mg / dl (> 0.6 mmol / l).Interference may occur when the concentration limit values for these substances are higher than those indicated below. Reducing substances normally present in the blood (uric acid, bilirubin) or following a treatment (ascorbic acid, paracetamol) do not modify the results significantly. contour XT can therefore be used by patients undergoing peritoneal dialysis using an icodextrin solution.īroad hematocrit range, 0 to 70%. The next contour test strips are provided with the enzyme FAD-GDH (flavin adenine dinucleotide glucose dehydrogenase) which has no interference with maltose, galactose, and oxygen. ) or exogenous (paracetamol, vitamin C, ascorbic acid. Thus, the glycemic results are not affected by the reducing substances present in the blood, whether of endogenous origin (bilirubin, cholesterol, triglycerides. The next contour strips feature a new Ascensia Diabetes Care Proprietary Mediator (BPM), an Ascensia Diabetes Care proprietary patented device. The new Contour Next USB set is especially accurate when blood glucose is low - which is important to help you detect and act on hypoglycemia (low blood sugar). This winning combination of indicator and sensor leverages innovative technology, giving you even better blood glucose results than those obtained in the lab. Very high measurement accuracy for your safety.Highly resistant to many environmental influences. ![]()
0 Comments
Read More
Leave a Reply. |